CGCLD - MOBILARMA 523, 667121-00
- MSDS: CGCLD
- Manufacturer: MOBIL OIL CORP
- Product Name: MOBILARMA 523, 667121-00
- National Stock Number: 9150-00N082196
Product Identification
Product ID:MOBILARMA 523, 667121-00
MSDS Date:09/07/1994
FSC:9150
NIIN:00N082196
MSDS Number: CGCLD
Responsible Party
FAIRFAX, VA 22037
US
Emergency Phone: 609-737-4411;800-424-9300(CHEMTREC)
Info Phone: 800-662-4525;703-849-3265
Cage: 3U728
Contractor
Telephone: 800-662-4525/ 856-224-4644
Cage: 3U728
Ingredients
PHOSPHORODITHIOIC ACID, O,O-DI C1-14-ALKYL ESTERS, ZINC
CAS: 68649-42-3
Fraction By Weight: 1.06%
OSHA PEL N/K
ACGIH TLV: N/K
ZINC (ELEMENTAL ANALYSIS) (SARA 313) (CERCLA)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 0.08%
OSHA PEL N/K
ACGIH TLV: N/K
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
0.221 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
EXAMINATION OF INTERNAL ORGANS & CLINICAL
RTECS: 9999999ZZ
BASE OILS IN PROD ARE SEVERELY SOLV
RTECS: 9999999ZZ
PAINTING STUDIES OF SEVERELY TREATED OILS SHOWED NO
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50 (ORAL,RAT): >2000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO SIGNIFICANT EFFECTS EXPECTED. ACUTE
TOXICOLOGY: INGEST: PRACTICALLY NON-TOXIC. SKIN: PRACTICALLY
NON-TOXIC. INHALATION: HARMFUL CONCENTRATIONS OF MISTS/VAPORS ARE
UNLIKELY TO BE ENCOUNTERED THROUGH ANY CUSTOMARY OR REASONABLY
FORSEEABLEHANDLING, USE, OR MISUSE OF PROD. EYE/SKIN IRRIT:
PRACTICALLY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HEALTH HAZARDS: NON-IRRITATING. SUBCHRONIC
TOXICOLOGY: SEVERELY SOLV REFINED & SEVERELY HYDROTREATED MINERAL
BASE OILS HAVE BEEN TESTED AT MOBIL ENVIRON & HLTH SCIENCES LAB BY
DERMAL APPLIC TO RATS 5 DAYS/WEEK FOR 90 DAYS AT DOSES
SIGNIFICANTLY HIGHER THAN THOSE EXPECTED DURING NORM INDUS EXPOS.
EXTENSIVE EVALS(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH THORO W/WATER FOR AT LEAST 15 MINS. IF IRRIT
OCCURS, CALL PHYS. SKIN: WASH CONT AREAS W/SOAP & WATER. INHAL:
REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE OXYGEN/ARTF RESP) .
INGEST: NOT EX PECTED TO BE PROBLEM. HOWEVER, IF >1/2 LITER(PINT)
INGESTED, IMMED GIVE 1-2 GLASSES OF WATER & CALL PHYS, HOSP EMER
ROOM/POIS CNTRL CNTR FOR ASSIST. DO NOT INDUCE VOMIT/GIVE ANYTHING
BY MOUTH (SUPDAT)
Fire Fighting
Flash Point Method:COC
Flash Point:>380F,>193C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER/FOAM MAY CAUSE FROTHING. USE TO FLUSH SPILLS AWAY FROM EXPOS.
PVNT RUNOFF FROM FIRE CNTRL/DILUTION(SUPDAT)
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST,
DIATOMACEOUS EARTH, ETC. SHOVEL UP & DISP OF AT AN APPROPRIATE
WASTE DISPOSAL FACILITY IN ACCORDANCE WITH CURRENT APPLICABLE LAWS
AND REGULATIONS, AND PRODUCT CHARACTERISTICS AT TIME OF DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NO SPECIAL PRECAUTIONS REQUIRED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER ORDINARY
CONDITIONS OF USE AND WITH ADEQUATE VENTILATION. USE NIOSH APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE
AND WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC: FROM ENTERING STREAMS, SEWERS/DRINKING WATER SUPPLY.
FIRST AID PROC: TO AN UNCON PERSON. WASTE DISP METH: GOVT APPRVD
WASTE DISP FACILITY. USE OF THESE METHS IS SUBJECT TO USER COMPLI
ANCE W/APPLIC LAWS & REGS & CONSIDERATION OF PROD CHARACTS AT TIME
OF DISP. EFTS OF OVEREXP: INCL MICROSCOPIC (ING 4)
Chemical Properties
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<0.1
Spec Gravity:0.883
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK AMBER LIQUID, MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE.
Disposal
Waste Disposal Methods:PROD IS SUITABLE FOR BURNING IN ENCLOSED,
CONTROLLED BURNER FOR FUEL VALUE/DISP BY SUPERVISED INCIN. SUCH
BURNING MAY BE LIMITED PURSUANT TO RCRA. IN ADDN, PROD IS SUITABLE
FOR PROCESSING BY AN APPRVD RECYCLING FACILITY/CAN BE DISP OF AT
ANY (SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.